Air-conditioners fail in recognisable ways: weak cooling, ice on the indoor coil, water dripping from the head, an error code on the display, or a unit that trips the breaker. Each points somewhere different, from a blocked drain and clogged filters to a refrigerant leak, a failed fan motor or a corroded control board.
We test the system as a whole before quoting parts: airflow, operating pressures, electrical draw, drainage and the condition of the outdoor coil. On the coast, corrosion often explains faults that look purely electrical, so we inspect terminals and boards for salt damage rather than swapping components until something works.
What the work covers
- Not cooling or cooling poorly
- Filter and airflow checks, refrigerant charge and pressure testing, coil condition and compressor operation.
- Water leaks and blocked drains
- Condensate tray and drain clearing, drain slope corrections, and checks for icing that is feeding the leak.
- Error codes and control faults
- Sensor, board and communication faults traced to the actual failed component rather than the code alone.
- Electrical and corrosion damage
- Terminal, capacitor, fan motor and board inspection on units exposed to salt air, with honest advice on repair versus replacement.
Llandudno coastal note
Salt air attacks the outdoor unit first: coil fins, fan blades, screws, terminal blocks and circuit boards. A repair on an exposed Llandudno unit should include cleaning and inspecting those parts, otherwise the same fault returns within a season. Where a board or motor has already corroded through, we tell you whether a repair is realistic or whether replacement is the better spend.